11
A7690C • 800-810-WIRE (9473) • www.sargentlock.com
4/15/08
Copyright
©
2008 SARGENT Manufacturing. All rights reserved.
Reproduction in whole or in part without the express written permission of SARGENT Manufacturing is pr
ohibited.
ATTACH RAIL ASSEMBLY
1. Depress chassis arm and slide rail assembly onto chassis
capturing the wire from the rail assembly in the wire holder
2. Feed the rail wire along the same path as the chassis wire
and snap the ElectroLynx connectors together. Wire tie
excess in bottom of chassis
3. Apply covers and strike pin. Refer to instruction sheet A6699
8500 Main Chassis Dwg
General Touch Bar
CAUTION – BEFORE STARTING:
• Check hand of door (This device is
handed and not reversible)
• Door should be fitted and hung
• Verify box label for size of exit device,
function and hand
• Install mullion in frame if used
Chassis
arm
Cover
Rail wire &
connector
Wire &
connector
Wire
holder
Guarded
latchbolt
Lock Down
Key —7/32”
hex key
To operate:
Depress pushrail,
insert hex key and
turn clockwise.
IMPORTANT: Surface of door
where exit device is to be
applied must be flush. Clear
away any raised projections to
allow exit device to rest on flat
surface of door
8500 Main Chassis Dwg
General Touch Bar
Chassis arm
Rail wire
connector
Wire connector
Wire
holder
Guarded
latchbolt
PREPARE DOOR AND MOUNT HARDWARE –
Refer to Instruction sheet A6699
Rail
assembly
Push rail
Rail
assembly
Push rail
APPLY STRIKE–CRITICAL TO MAINTAIN
GUARDING OF LATCHBOLT
1. Determine proper position of strike by closing
door after mounting chassis and rail. Position
strike on frame or mullion, so that the
latchbolt is
extended/engaged but the guard is held
retracted
. Mark location of slotted holes and drill
and tap (2) holes for the oval head screws
2. For the 59-8800 hardware, fasten the strike to the
frame or mullion with (2) star washers in between
strike and frame and tighten (2) screws.
Ensure
guard remains retracted when door is closed
3. For the 12-59-8800 hardware, attach the strike
to the frame or mullion with (2) oval head screws
4.
Check strike placement again by closing
door and ensuring the guard is held retracted
(latchbolt guarded). Drill and tap (2) holes for
round head screws and fasten strike in place
5. Ensure latchbolt is guarded by depressing it.
The latchbolt must fully project/extend when
the door is closed for the guarding to work. Finish
installation per instruction sheet A6699 and
Section 10 within this manual
Strike
Guard
Chassis wire &
connector
8828 shown
Exit Device Installation (continued)
Installing 59-8500/12-59-8300 Series Narrow Design Rim Exit Devices
Vertical reference line CL chassis
A7690C.indd 11