Chapter II Functions & Features
46
ARRAY
If the load goes wrong, the input will be shut down with beeps, and the LCD will display the
detected conditions and the load will enter into the latched protection status. And the
corresponding state bit in the register will be set. Except some specific operations, the load will
not respond to other commands. For example: If an overtemperature condition has been detected,
the input will be turned off with beeps. And the OT will be shown in the lower right corner of the
LCD and the load will have no response to other operation commands.
2.12.1 Clearing Latched Function
When the load enters the latched protection state, it will not respond to any other commands. It wil
return to normal operation only after clearing the latched protection via compound keys
and
, or via the remote command: INPut:PROTection:CLEar. Of course the condition that
cause the latch protection must be cleared, otherwise it will cause the latched protection again
immediately.
In addition, when the software current protection function is enabled, if the overcurrent time does
not exceed the set protection time, the load will display PT to indicate, but the input will not be
turned off. At this time, user can reset the overcurrent time via compound keys
and
,
or via the remote command: INPut:PROTection:CLEar.
2.12.2 Overvoltage
The overvoltage alarm level is set at a predetermined voltage, which cannot be changed by the
user. When the voltage exceeds this predetermined voltage, the overvoltage protection will be
enabled, and the input is turned off with OV display. Meantime, the OV and VF status register bits
are set and remain until they are reset and the overvoltage condition is removed.
2.12.3 Overcurrent
The load allows the user to define a current protection limit. When the defined current limit is
exceeded, the input will not be turned off immediately but the overcurrent timer will start to time,
and the display will show PT to indicate the protection status. When the specified delay time is
Summary of Contents for 3750A
Page 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Page 63: ...Chapter III Installation 59 ARRAY ...
Page 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Page 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Page 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Page 120: ......