![Array electronic 3750A Manual Download Page 73](http://html1.mh-extra.com/html/array-electronic/3750a/3750a_manual_2975640073.webp)
Chapter IV Local Operation
69
ARRAY
POW
1000
;
Set the power level
INP
ON
;
Open the load
Example 2:
Take 3751A as an example, in CRH mode, set the load to CP mode, the power level
to 1000W, the VON voltage to 15V, the power limit to 1200W, the current rising rate 10A/us and
the current falling rate 6A/us. Turn on the load. The procedures are shown as below:
Step 1:
Press
key to enter into
mode and parameter setting menu;
Step 2:
Switch to parameter setting menu via
and
keys;
Step 3:
Move the cursor to the thousand position via the
key, then enter number 1 via the
knob or the number keypad; move the cursor to other positions via the
key, then enter
number 0 via the knob or the number keypad; then press
key to confirm;
Step 4:
Switch to VON voltage option via
and
keys;
Step 5:
Move the cursor to the ten position via the
key, then enter number 2 via the knob or
the number keypad; move the cursor to the digit position via the
key, then enter number 0
via the knob or the number keypad; then press
key to confirm;
Step 6:
Switch to current limit option via
and
keys;
Step 7:
Move the cursor to the ten position via the
key, then enter number 7 via the knob or
the number keypad; move the cursor to the digit position via the
key, then enter number 0
via the knob or the number keypad; press
key to confirm;
Step 8:
Switch to current rising rate option via
and
keys;
Step 9:
Move the cursor to the ten position via the
key, then enter number 1 via the knob or
the number keypad; move the cursor to other positions via the
key, then enter number 0 via
the knob or the number keypad; press
key to confirm;
Step 10:
Switch to current falling rate option via
and
keys;
Summary of Contents for 3750A
Page 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Page 63: ...Chapter III Installation 59 ARRAY ...
Page 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Page 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Page 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Page 120: ......