1.6.5.5 +CV Mode Menu
Description
:
+CV mode can be added to CC, CR and CP mode. For more details on +CV Mode,
please refer to Page 60.
Voltage Value
To display the current input terminal voltage;
Power Value
To display the current power value;
Current Value
To display the current value
Mode
CCL indicates constant current low range;
+CV indconstant voltage mode;
Input State
ON/OFF;
Run Time
To display the time the load being ON, reset when shutdown or
switch mode;
Para Set
To set the constant current value, unit: A;
Volt Start
To set the start voltage of the load,
0 indicates the function being not enabled;
Curr Limit
To limit the maximum Current level at the mode
RiseRate
To control the current rising rate when starting
FallRate
To control the current falling rate when stopping
key
Press this dynamic key to return to the main menu;
key
Press this key to switch between CCL and CCH;
key
Press this key to enter the transient operation;
key
Press this key to enter list operation.