![Array electronic 3750A Manual Download Page 48](http://html1.mh-extra.com/html/array-electronic/3750a/3750a_manual_2975640048.webp)
Chapter II Functions & Features
43
ARRAY
Fig. 2-15 Current Falling Rate
2.8 Measurement Function
The load has high resolution measurement function, which can measure the voltage and the
current in realtime. The input power level and the resistance level can be computed with the input
voltage level and the current level. The measured level can be checked through LCD display
directly or be read via the remote commands:
MEASure:VOLTage?;
MEASure:CURRent?;
MEASure:RESistance?;
MEASure:POWer?
2.9 Saving and Recalling
The load has EEPROM memory, which can be used to save various parameters, such as modes,
input status, current, voltage, resistance, transient settings, protection levels, etc. The 375XA
electronic load can save 10 groups of parameters. All parameters relevant to saving and recalling
operation are listed in Table 2-1 (Take 3751A as an example.).
Table 2-1
Function
Effect
Default
Input
Input Status
Off
Mode
Operation Mode
CCH
Current
Immediate Current Level
0A