Chapter II Functions & Features
28
ARRAY
immediate resistance level automatically when a trigger is received. In CR mode, if the input of
the load is ON, the input resistance value will be updated immediately when a trigger occurs. If it
is not in CR mode, the level will not affect the load until the CR mode becomes enabled.
The triggered resistance level can only be set via remote command: RESistance:TRIGgered
<NRf+>. Once a triggered resistance level is triggered, the subsequent triggers will have no effect
on the input unless another new triggering signal is sent. The trigger operation will be described in
later chapter. The status register of the load can keep track of pending triggers and other operation
conditions, which will be described in details in
《
ARRAY 375XA Electronic Load SCPI
Programming Guide
》
.
2.3.3.4 Transient Resistance Level
In transient resistance operation mode, the load can continuously toggle between the two levels:
the transient resistance level and the immediate resistance level. The transient resistance level can
be set in the transient operation menu or via the remote command: RESistance: TLEVel <NRf+>.
2.3.4 CP Test
The constant power mode is the constant power-voltage source mode, being suitable for the
voltage source test. In CP mode, the load will consume a constant power from the power source
regardless of the external current and voltage change to meet U*I=P, as shown in figure 2-4. In
basic operation state, press
key to enter the mode and parameter set menu, then enter the
power value via the keypads or knob combining with
and
keys, finally confirm the
setting with
key. The CP mode and the parameters can also be set via the remote
commands:
MODE CP
POWer <NRf+>
Summary of Contents for 3750A
Page 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Page 63: ...Chapter III Installation 59 ARRAY ...
Page 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Page 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Page 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Page 120: ......