![Array electronic 3750A Manual Download Page 41](http://html1.mh-extra.com/html/array-electronic/3750a/3750a_manual_2975640041.webp)
Chapter II Functions & Features
36
ARRAY
Then after 200us duration of falling edge, the current returns to the transient low level (5A).
Fig. 2-7 Pulsed Transient Operation
2.4.3 Toggled Transient Operation
The trigger function is required for toggled transient operation. When there is no trigger occurs,
the load remains at the transient level. After a trigger has been received, a toggle operation will be
executed and the other transient level will be reached after the duration of the rising edge or the
falling edge. The associated parameters such as transient low level (LevelL), transient high level
(LevelH), transient high level (LevelH), time for rising edge (TimeR), time for falling edge
(TimeF) and toggled transient mode can be set through transient operation menu or via the
followed remote command:
CURRent <NRf+>
To set the transient current low level;
CURRent:TLEVel <NRf+>
To set the transient current high level;
VOLTage <NRf+>
To set the transient voltage low level;
VOLTage:TLEVel <NRf+>
To set the transient voltage high level;
RESistance <NRf+>
To set the transient resistance low level;
RESistance:TLEVel<NRf+>
To set the transient resistance high level;
TRANsient:RTIMe <NRf+>
To set the time for transient rising edge;
TRANsient:FTIMe <NRf+>
To set the time for transient falling edge;
TRANsient:MODE TOGGle
To set the toggled operation mode;
The trigger can be produced by the signal from the external trigger terminal, or via the remote
command *TRG. It is need to do the trigger initial operation before the trigger operation,
otherwise the load won’t response to the trigger.
For example: assume that the CCH range is active, and the input of the load is OFF, then the
Summary of Contents for 3750A
Page 1: ...Contents USER S MANUAL 375X SERIES ELECTRONIC LOAD ...
Page 63: ...Chapter III Installation 59 ARRAY ...
Page 114: ...Chapter V Remote Programming Operation 110 ARRAY Frame Diagram Fig 1 ...
Page 115: ...Chapter V Remote Programming Operation 111 ARRAY ...
Page 116: ...Chapter V Remote Programming Operation 112 ARRAY Fig 2 ...
Page 120: ......