46
ATS4000 Manager’s Guide
4.
Enter the month number and press [ENTER], [ENTER]
5.
Select:
1: DST end at FIRST Sunday of the month
2: DST end at LAST Sunday of the month
6.
Press [ENTER], [ENTER] to accept
Enter the month number when the time changes from summertime to wintertime and
press [ENTER]
The programming of DST is completed
To adjust the internal clock for correct timings
Enter option 4
Press
[MENU*]
to change the sign and give the correction number of seconds to add or
to substract daily. Then press
[ENTER]
.
16. I
NHIBIT
/
UNINHIBIT
RAS/DGP
Use this function to inhibit remote arming stations (RASs) and data gathering panels
(DGPs), i.e. exclude fault and tamper messages (system alarms) from a RAS or DGP to
the security system.
This function is used if a RAS or DGP has generated a system alarm, or is out of service,
and needs to be inhibited while awaiting service.
2- Last Sunday, Month 3
End Day:
2- Last Sunday, Month 00
End Sunday
Daily Adjustmemt (Sec).: +0
*-Change, sec:
2- Last Sunday, Month 10
End Month
Intelligent Security & Fire Ltd.