36
ATS4000 Manager’s Guide
13. S
TART AUTO
DISARM
TEST
Use this function to start the disarm test.
To start the disarm test
1.
Access menu option 13.
The display shows:
2.
Press:
[NEXT]
to display the untested zones, or
0
and
[ENTER]
to cancel the arm test and move on to test completed/not completed
display.
3.
If you have pressed [NEXT], the untested zones are displayed either one at a time or
as a list:
Zones displayed one at a time
Zones displayed as a list
For example:
For example:
4.
For either display, you can now:
Option
Action
Display the description of the selected zone (when
displayed as a list of numbers only)
Enter the zone
number and
press
[ENTER]
Display the remaining untested zones (if any)
Press
[NEXT]
Move on to the Camera Test or Test Completed/Not
Completed display.
Press
[ENTER]
5.
The display might shows information about cameras:
Press
[ENTER]
to return to the original option display.
Note that only cameras allocated to Area 1 are tested.
6.
The testing automatically stops when:
•
When all zones that are programmed to be tested during disarm test have been
tested, or
•
The time allowed for the disarm test has expired.
The display then indicates if the test is completed or not.
Disarm Test, NEXT For Untested
"0"-Cancel:
:
Untested Disarm On 4. PIR In Office
NEXT or ENTER
Untested On 1, 2, 4.
Zone No:
All Cameras Have Tested Successfully
Press ENTER
Intelligent Security & Fire Ltd.