PiCUS TMSO Manual
67
TMSO.CU:
Column Designation
Description
1
unix time [s]
UNIX timestamp of this line
2
battery [V]
Battery voltage in Volt
3
temperature [°C]
Temperature in °C
4
relative humidity [%]
External relative humidity in %
5
solar efficiency [%]
Time the solar cell was illuminated enough to deliver energy to
the device, in % of total time
6
cloud
connection
errors
Number of unsuccessful attempts to connect to the cloud
Indicator for problems with the Internet connection
7
system errors
Number of occurred errors (not critical), for error analysis by the
device manufacturer
8
status flags
pos.
+
-
1
Measuring mode
Sleep mode
2
Normal
Energy-saving mode
3
Internet connection OK
No Internet connection
4
Cloud access OK
No cloud access
5
Tilt sensor OK
Tilt sensor defective
6
Temperature sensor OK
Temperature sensor
defective
7
Humidity sensor OK
Humidity sensor defective
8
Buffer memory OK
Buffer memory defective
9
Backup memory OK
Backup memory defective
10
TMS Radio OK
TMS Radio defective
9
max. inclination
dimensionless comparison value, represents the largest
inclination that occurred during the last measuring cycle
Table 4 - Log file contents TMSO.CU block
TMSO.IM:
Column
Designation
Description
1
battery [V]
Battery voltage in Volt
2
temperature [°C]
Temperature in °C
3
solar efficiency [%]
Time the solar cell was illuminated enough to deliver energy to
the device, in % of total time
4
signal quality [%]
+
Radio link to this TMSO.IM OK
-
TMSO.IM has not responded
The number indicates the percentage of messages successfully
sent to this sensor
5
radio
connection
errors
Number of failed attempts to transmit a message to this TMSO.IM
6
system errors
Number of occurred errors (not critical), for error analysis by the
device manufacturer
7
status flags
pos.
+
-
1
Tilt sensor OK
Tilt sensor defective
2
Temperature sensor OK
Temperature sensor
defective
3
Buffer memory OK
Buffer memory defective
8
max. inclination
dimensionless comparison value, represents the largest
inclination that occurred during the last measuring cycle
Table 5 - Log file contents TMSO.IM block
If you look at an individual log file however, you will miss the assignment of the information
blocks to the actual devices (via the serial numbers)!
The easiest way to get this information is to display the system status in the TMS.Software.
The listing order of the devices there corresponds to the sequence of the information blocks in
the log file.