PiCUS TMSO Manual
57
The result of the test is a block with information about the status of the central unit as well as
a list with the status of each registered sensor.
If critical errors have occurred during the test that prevent the system from being activated this
will be indicated by extra message windows.
Now you should take a closer look at the reported status of the system!
The TMSO.CU:
The battery condition should be
Good
or
Full
.
If the battery is discharged too much, it must
be expected that the central unit will go into
energy-saving mode early or even fail
completely.
The status flags should be a row of
+
-
symbols.
A
-
- symbol indicates a hardware error (see
).
The TMSO.IM:
The sensor list shows all sensors registered
in the project.
The battery condition should be
Good
or
Full
If the battery is discharged too much, it must
be expected that the sensor will fail
prematurely.
The quality of the radio connection should
be more than 70% with a
+
- symbol in
front.
The percentage represents the ratio of
successfully transmitted test messages
between TMSO.CU and this sensor. If the
value is too low, it must be expected that the
communication will often fail and measurement data may be lost.
A
-
- symbol means that the sensor could not be successfully configured and therefore
cannot function properly if the system is activated anyway.
The status flags should be a row of
+
- symbols.
A
-
- symbol indicates a hardware error (see
If you are satisfied with the result of the system test you can continue with the next and last
step.