ES-6
Electrical System
Argo Service Manual
Ontario Drive & Gear Limited
www.argoutv.com
PH.(519)- 662-2840 FAX (519)- 662-2421
Remove the empty electrolyte container from
the battery. Fully insert the strip of sealing
caps (previously removed from the electrolyte
container) into the battery filling ports. Make
sure the strip of caps is fully inserted and flush
with the top of the battery. Insert the caps by
hand, do not use a hammer or excessive force.
Never remove the strip of caps or add water or
electrolyte to the battery during its service life.
After filling, the sealing caps should be installed using hand pressure only. The sealing
cap should never be removed once the battery is activated.
For batteries with ratings of less than 18 AH, let the battery stand for 20 to 60 minutes.
For batteries with higher AH ratings, and/or having the High Performance rating
(designated by an “H” in the part number/name) allow the battery to stand for 1 to 2
hours. Yuasa AGM batteries have the amp hour (AH) printed on the front of the battery
case. The stand, or rest period, allows the electrolyte to permeate into the plates for
optimum performance.
Newly activated AGM batteries require an initial charge. After adding electrolyte, a
new battery is approximately 75-80% charged. After the “stand” period (step 6), charge
the battery to bring it to a full state-of-charge. The battery charger used for initial
charging should be able to charge at 12.8+-volts for an AGM battery. All Yuasa battery
chargers are capable of reaching this minimum voltage and initializing/activating an
AGM battery.
Points to Remember
■ Newly activated AGM and Conventional batteries require an initial charge
before being placed into service
■ Yuasa Smart Battery Chargers use constant current and pulse technology and
can activate, charge and maintain all Yuasa batteries
■ High-rate, automotive types of chargers can cause damage to powersports
batteries
■ High performance batteries (designated by an “H” in the part number) must
stand 1 to 2 hours after initial charging
■ Never remove the strip of caps on an AGM battery to add water or electrolyte
during its service life
■ Before activation of Conventional batteries remove the red sealing cap from
the vent elbow and discard it
ES INDEX
MAIN INDEX
Summary of Contents for All 6X6
Page 1: ...Printed in Canada 2022 01 01 All 8X8 MODELS All 6X6 MODELS SERVICE MANUAL 2022...
Page 2: ......
Page 252: ...TR 74 Argo Service Manual Transmission TR INDEX MAIN INDEX...
Page 255: ...TR 77 Argo Service Manual Transmission TR INDEX MAIN INDEX...
Page 268: ...TR 90 Argo Service Manual Transmission Press 101 01 Bearing onto shaft TR INDEX MAIN INDEX...
Page 271: ...TR 93 Argo Service Manual Transmission IDLER SHAFT ASSEMBLY TR INDEX MAIN INDEX...
Page 277: ...TR 99 Argo Service Manual Transmission TR INDEX MAIN INDEX...
Page 286: ...TR 108 Argo Service Manual Transmission TR INDEX MAIN INDEX...