5-7
5
8. Connect the red MaxiClip to the blue wire; then
connect a voltmeter to the MaxiClips (red meter
lead to red and black meter lead to black).
9. Set the meter selector to the DC Voltage posi-
tion; then turn the ignition switch to the
LIGHTS position and the light control switch to
the HI beam position. The tester must indicate
battery voltage and the high beam indicator light
(15) must illuminate. If the tester does not read
battery voltage, troubleshoot the ignition switch,
light control switch, or wiring harness and con-
nectors.
10. Connect the red MaxiClip to the brown/black
wire. The tester must read battery voltage and
the speedometer backlight (5) must illuminate.
If the tester does not read battery voltage, trou-
bleshoot the ignition switch or wiring harness
connectors.
11. Depress and hold the Mode/Set button (1). The
speedometer should switch between mph and
km/h as indicated by icon (12).
12. Depress and hold the Mode/Set button (2). The
distance mode should shift between ODO and
TRIP as indicated by icon (12).
13. Depress and hold the Mode/Set buttons (1) and
(2) simultaneously. The hour segment of the
clock should flash indicating the clock (13) is in
the set mode. Release the Mode/Set button (2)
and release when the desired hour (1-24)
appears.
14. Depress and release the Mode/Set button (1) to
shift the clock set to the minute segment; then
depress Mode/Set button (2) to set the desired
minute.
NOTE: In the clock set mode, the gauge will
default to normal operation 10 seconds after the
Mode/Set buttons are released.
15. With the ignition switch in the ON position, use
a small screwdriver or suitable tool to spin the
input quill of the speedometer. The speed indi-
cator (6) must indicate a value greater than zero.
INSTALLING
To install the LCD gauge assembly, see Section 9 of
this manual.
Ignition Switch
The connector is the white one beneath the front
cover. To access the connector on the Utility model,
the front rack and front cover must be removed (see
Section 8).
VOLTAGE
NOTE: Perform this test on the lower side of the
connector.
1. Set the meter selector to the DC Voltage posi-
tion.
2. Connect the red meter lead to the red/white
wire; then connect the black meter lead to
ground.
3. The meter must show battery voltage.
NOTE: If the meter shows no battery voltage,
troubleshoot the battery, 30 amp fuse, or the main
wiring harness.
RESISTANCE
NOTE: Perform this test on the upper side of the
connector.
1. Turn the ignition switch to the ON position.
2. Set the meter selector to the OHMS position.
3. Connect the red tester lead to the red wire; then
connect the black tester lead to the black wire.
4. The meter must show less than 1 ohm.
5. Turn the ignition switch to the LIGHTS posi-
tion.
6. Connect the red tester lead to the red wire; then
connect the black tester lead to the brown wire.
7. The meter must show less than 1 ohm.
NOTE: If the meter shows more than 1 ohm of
resistance, replace the switch.
! CAUTION
Always disconnect the battery when performing
resistance tests to avoid damaging the multimeter.
Back to TOC