Changes
- Terminology consistency improved (e.g. binary inputs are now always called digital inputs).
- Tech data modified to be more informative about what type of measurement inputs are used (phase currents/
voltages, residual currents/voltages), what component of that measurement is available (RMS, TRMS, peak-to-
peak) and possible calculated measurement values (powers, impedances, angles etc.).
- Tech data updated: non-directional overcurrent
- Tech data updated: non-directional earthfault
- Tech data updated: directional earthfault
- Tech data updated: current unbalance
- Improvements to many drawings and formula images.
- Improved and updated IED user interface display images.
- AQ-T215 Functions included list Added: Running hour counter, under- and overfrequency, rate-of-change-of-
frequency, overpower, underpower, reverse power, voltage memory, indicator objects, cold load pick-up, vector
jump protection, synchrocheck, fault locator, programmable control switch, mA output control and measurement
recorder.
- Added "32N" ANSI code to directional earth fault protection modes "unearthed" and "petersen coil grounded".
- Added 6th harmonic to harmonic overcurrent protection function.
- Added BCD and binary input coding description to automatic voltage regulator description.
- Changed disturbance recorder maximum digital channel amount from 32 to 95.
- Added residual current coarse and fine measurement data to disturbance recorder description.
- HSO1 and HSO2 connection swapped in arc protection card (was way wrong before).
- Updated I01 and I02 rated current range.
- Added inches to Dimensions and installation chapter.
- Added raising frames, wall mounting bracket, combiflex frame to order code.
- Added logical input and logical output function descriptions.
- Additions to Abbreviations chapter.
- Added button test description to Local panel structure chapter.
- Added Fault register view to Basic configuration chapter.
- Added parameter descriptions to General menu IED user interface chapter.
- Protection IED user interface chapter almost completely rewritten and restructured.
- Added new parameter descriptions to Monitoring menu IED user interface chapter.
- Added note to Configuring user levels and passwords chapter that user level with a password automatically locks
itself after 30 minutes of inactivity.
- Added more "Tripped stage" indications and fault types to Measurement value recorder function.
- Updated: Digital input activation and release threshold setting ranges and added drop-off delay setting.
- Added sample rate to voltage and current measurement tech data.
- Fixed overvoltage, undervoltage, neutral overvoltage and sequence voltage stage misspelled IDMT curve
formula.
Revision
2.04
Date
8.6.2021
A
AQ
Q-T215
-T215
Instruction manual
Version: 2.04
7