10
GA 7000C-E-0313
© 2013 by arcomed ag, Switzerland
All functions can also be accessed by the key panel, using I, II and DATA keys. Data is
entered / changed in the DATA and the RATE window.
Further characteristics of the LCD:
-
The large size of the display allows to display the vital values in large fonts so they can
be read easily from a large distance
-
The color display allows labelling drugs not only with names but also with colors (Med
Marker). If consistent color labelling is used drugs or drug classes can be easily identified
which is especially helpful if a large number of drugs are used on the same stack.
-
Both text color and background color can be configured. Contact your pump administrator
for customized drug labelling.
-
Alarm messages are displayed with a RED background (Alert Scout).
-
Alert (pre alarm state) can be displayed in colors (Alert Scout).
-
Colored icons allow to easily and quickly find the application or selection desired.
-
Values that can be changed in the RATE or DATA window are displayed in RED for easy
identification of the setting parameters.
3.1.2
Setting of paramters:
The Volumed® µVP7000 Chroma is equipped with the possibility of touch screen operation.
-
The touch screen may be activated or disabled, depending on the options and settings of
your pump
-
The touch screen is a resistive technology and needs a certain amount of pressure to be
activated. This increases the safety of the pump and avoids accidental touch presses e.g.
by drips falling on the pump. On the other hand, the touch screen can also be operated
with gloves.
-
You might notice a very short delay between the press on the screen and the reaction of
the pump. This is normal and increases the accuracy of the touch screen.
-
The touch screen does only support single presses. Multi finger gestures are not
supported by resistive technology.
-
When swiping or pressing over the screen, no action will happen until the finger is
removed. The pump will activate the last item selected.
-
You will see most icons shortly changing its size when it’s pressed. If audible feedback is
activated, a short beep also confirms a touch selection.
-
For safety reasons some functions CAN NOT be accessed through the touch screen, e.g
starting a bolus must be confirmed with a key on the panel. The Icon on the screen will
indicate this with an arrow which key has to be activated. If the user still tries to access
the function through the touch screen, a warning message will appear to indicate the key
to be pressed.
-
The pump can only be started or stopped with the START/STOP key on the panel for
safety reasons. The stop and running icon on the screen will not start or stop the pump.
-
The bottom line of the screen contains in most windows the navigation icons.
-
In the main window the menu can be accessed with the MENU icon that will a list of
applications that are available.
NOTE:
The pump can be configured to hide certain functions. Therefore, depending to the
configuration of your pump some functions might not be visible. Contact your administrator of
pumps if functions needed are not visible.
-
The pumps can be furthermore configured with additional icons at the bottom line of the
main window, so called short cuts. These short cuts will bring you directly to a desired
function or information with one press.