© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
S
ECTION
5: A
QUA
-H
OT
C
OMPONENTS
Control Thermostat Replacement Procedure:
F
AILURE
TO
DISCONNECT
ALL
POWER
SUPLIES
AND
/
OR
TO
ALLOW
THE
HEATER
TO
COOL
BEFORE
SERVICING
COULD
CAUSE
SERIOUS
DAMAGE
OR
PERSONAL
INJURY
.
1.
Ensure that the Aqua-Hot has been completely shut
down and that all power sources have been disconnect-
ed. Also, because this replacement procedure will in-
volve the boiler tank and the potential for hot coolant, be
sure the heater has adequately cooled.
2.
Disconnect the defective control thermostat’s wires by
removing the screws securing the wires to the terminals.
3.
Using a 1/4” nut driver, unscrew the two screws secur-
ing the control thermostat to the Aqua-Hot’s boiler tank
thermostat mounting bracket.
4.
Install the replacement control thermostat into the ther-
mostat mounting bracket and secure with the two screws
previously removed.
5. Inspect the wires going to the control thermostat Re-
place if necessary. Re-Connect the control thermostat’s
wires and secure in place using the screws previously
removed.
6.
Test the Aqua-Hot for normal operation.
Figure 9
Note:
If a screw longer than 1/4” is used to secure the
thermostat in place, it may cause the thermostat mounting
bracket to be pushed away from the boiler tank, and may
result in overheating.
NOTE:
The Motor Home must be plugged into shore pow-
er, or the generator must be operating for the electric ele-
ment to be working.
Summary of Contents for AHE-100-02S
Page 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Page 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 105: ... Page 105 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...