— Page 49 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
1. Check “Fuel Solenoid Valve”
wires for continuity. Replace
wires if necessary.
2. Replace “Control Unit” if wires
indicate continuity.
3. Retest fuel flow (without Fuel
Nozzle)
4. Install “Fuel Nozzle”.
5. Retest Fuel Nozzle spray pattern
(fine mist of fuel present?).
6. Reattach “Diesel Burner Head”
and attempt heater restart.
1. Turn the Control Switch OFF.
2. Replace “Fuel Nozzle”.
3. Retest Fuel Nozzle spray pattern
(fine mist of fuel present?).
4. Reconnect ignition wires to
“Ignition Electrodes” or remove
jumper wires.
5. Reattach “Diesel Burner Head”
and attempt heater restart.
NOTE: If an improper fuel spray is still observed (a normal spray
pattern should be observed as a coned-shaped mist) the Diesel
Burner’s “Fuel Pump” should be calibrated for the proper fuel
pressure setting.
End of Troubleshooting Flow Chart.
For additional troubleshooting information please contact:
Aqua Hot Heating System’s Service Department
at 303-659-8221
Mon-Fri
7:00 a.m. - 4:00 p.m.
S
ECTION
8: D
IESEL
-B
URNER
C
OMPONENTS
/T
ROUBLE
S
HOOTING
Summary of Contents for AHE-100-02S
Page 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Page 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 105: ... Page 105 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...