— Page 71 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
1. If The Heater Smokes on Start up/Shut down.
a. Fuel solenoid
- plunger worn out
- plastic/metal in the way of plunger
- fuel solenoid intermittent.
b. Nozzle Tower
- cracked
- poorly machined
c. Short cycling
- control t-stat bad
- someone turned heater off/on repeatedly
d. Return Fuel Check Valve
-
heaters manufactured before 2001
2. If The Heater Smokes During The Burn Cycle.
a. Electrodes out of adjustment
b. Air in the fuel system
c. Bad nozzle
d. Fuel pressure
e. Fuel Pump
f.
Intermittent Ignition Coil
- If the coil doesn’t turn on, the fuel sprays for 20 seconds, before the photo eye
shuts the fuel off.
S
ECTION
9: G
ENERAL
T
ROUBLESHOOTING
I
F
T
HE
A
QUA
-H
OT
IS
B
LUE
/W
HITE
S
MOKING
:
NOTE:
It is normal for the heater to blue/white
smoke for 3-5 seconds on start up and shut down.
Summary of Contents for AHE-100-02S
Page 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Page 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 105: ... Page 105 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...