— Page 100 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
A
PPENDIX
E: A
QUA
-H
OT
M
AINTENANCE
Step 12: Inspect Photo Disc
Photo Disc
1. If the photo disc is not free floating, the electrode clamp bolt has been over-tightened, and has bent the electrode clamp. Using a
10mm socket remove the electrode clamp, and re-straighten.
-Lay the clamp’s beveled side down on a solid flat surface and align the thick end of the punch at dead center. Tap the
punch lightly until the retaining clamp returns to proper form.
Step 13: Re-Install Diesel Burner
1. Align the Diesel-Burner with the Aqua-Hot, using the alignment tabs welded on the Aqua-Hot.
2. Swing the Eye Bolts around the “Ears” on the diesel burner and securely tighten, using a 10mm socket with a 10
inch long extension.
NOTE: When reinstalling the diesel burner be careful not to damage the photo disc or bend the electrodes.
Also, be careful to not pinch any wires between the burner and the Aqua-Hot Tank.
Use extreme caution when tightening down the eye-bolt nuts, over tightening of the eye-bolt nuts can
cause the aluminum blower casing to crack. (Torque Specifications = Approximately 20-40 in. lbs.)
Figure E12
Figure E13a