— Page 32 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
S
ECTION
5: A
QUA
-H
OT
C
OMPONENTS
2. Drain the antifreeze and water heating solution from the
Aqua-Hot’s boiler tank using the drain valve.
3.
Remove the Electric Element access cover.
4.
Remove the two wires secured to the defective electric
heating element by releasing the screw terminals.
5.
Using a 1-1/2 inch socket, remove the defective electric
heating element from the Aqua-Hot boiler tank.
6.
Install the replacement 1650-watt electric heating ele-
ment into the boiler tank ensuring that the “up” lettering
on the element is installed in the up position.
7.
Connect the wires removed from the defective electric
heating element to the replacement electric heating ele-
ment and tighten the screw terminals.
8.
Reinstall the Electric Element access cover.
9. Refill the Aqua-Hot’s boiler tank with the antifreeze and
water heating solution.
10. Test for proper operation
VAC Access
Panel
Thermostats
Electric Element
Figure 20