Step 6: Clean and Inspect the Combustion Chamber and Heat Transfer Tabs.
1. Remove the combustion chamber by pulling it
straight out, approximately 16 inches.
Use caution when handling the combustion chamber, it may be extremely
hot, and serious burns could result from touching a hot combustion chamber.
2. Once the combustion chamber has been removed.
Use a long handled wire brush, and brush the heat trans-
fer tabs, to loosen soot deposits. Failure to do so will
reduce the Aqua-Hot’s heat transfer capabilities.
Heat Transfer
Tabs
NOTE
: If the heat transfer tabs are excessively sooty, it may be necessary to vacuum the soot out of the heat transfer
tabs. If there is a minimal amount of soot, it may be left in the heat transfer tabs, and will be evacuated out the exhaust
pipe, upon start up of diesel burner.