— Page 75 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
S
ECTION
9: G
ENERAL
T
ROUBLESHOOTING
I
F
T
HERE
I
S
A
NTIFREEZE
L
EAKING
: (
CONTINUED
)
2. On the Top-Side of Aqua-Hot -
1. Expansion Tank Connection
a. Cracked expansion tank tubing
b. Radiator Cap
c. Filler neck/Filler neck solder joing
2. Supply/Return Ports
A. Defective fitting
B. Leaking fitting
Note: If no leaks are found on the Aqua-Hot, it is possible
that there is a leak within the motor home. Check all Heat
exchangers, connections, and tubing for leaks.