3. Inspect the combustion chamber for damage or signs of warping.
1. Inspect the combustion chamber for cracks appearing along the seam of the stainless steel tube.
A. If the crack is over 1” in length, the combustion chamber must be replaced.
2. Inspect the aluminum Air Swirler for signs of warping. If any part of the air swirler is warped the
combustion chamber must be replace.
A. Inspect the outer ring that the photo disc seats against for signs of warping.
B. Inspect the back side of the Air Swirler for signs of warping between screws.
Step 6: Clean and Inspect the Combustion Chamber and Heat Transfer Tabs.
Seam on stain-
less steel tube
Outer ring that the photo
disc seats against
Back side of air
swirler
Figure E6c