— Page 39 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
S
ECTION
7: D
ETACHING
AND
R
EATTACHING
THE
D
IESEL
B
URNER
Instructions for Detaching the Diesel Burner
WARNING!
Be sure to move the Diesel-Burner switch on the Interior Switch Panel to the OFF position and disconnect the
Diesel-Burner’s power supply before detaching the Diesel-Burner from the Aqua-Hot. Failure to turn off the
Diesel-Burner and disconnect power could result in serious bodily injury.
CAUTION!
Be sure to clamp off the Fuel Supply and Return lines at the ports on top of the Aqua-Hot prior to beginning this
replacement procedure.
Step 1: Turn Off the Diesel Switch
1. Move the Interior Switch Panel’s Diesel-Burner switch to the “OFF” position.
1. Remove the Aqua-Hot’s access cover by locating
the screws securing it in place.
2. Unscrew the screws securing the cover in place.
Step 2: Remove the Access Cover
Figure 27
Figure 28
Summary of Contents for AHE-100-02S
Page 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Page 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...