— Page 33 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
from the flame is transferred to the antifreeze and water heat-
ing solution where it can be used for each system of the Aq-
ua-Hot - domestic hot water, interior heat, and engine pre-
heat.
S
ECTION
6: D
IESEL
-B
URNER
O
VERVIEW
Diesel-Burner Overview
The Aqua-Hot’s diesel-burner is a device that ignites a mix-
ture of diesel fuel and air within a controlled setting to serve
as a heat source. The flame is established in a combustion
chamber within the Aqua-Hot’s boiler tank, and the heat
Figure 21
Figure 22
Controller
Diode Wire
Ignition Coil
Electrode
Adjustment
Gauge
Fuel Solenoid
Fuel Nozzle
Fuel Pump
Flame Sensor