Step 4: Remove the Diesel Burner from the Aqua-Hot
1. The Diesel-Burner is secured to the Aqua-Hot with two nuts that can be loosened,
and swung out of the way by using a 10mm socket wrench with a 10 inch long exten-
sion.
2. Carefully pull the Diesel-Burner away from the Aqua-Hot 4 to 5 inches before
rotating the burner, and then remove.