— Page 42 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
S
ECTION
7: D
ETACHING
AND
R
EATTACHING
THE
D
IESEL
B
URNER
Step 6: Disconnect the Fuel Lines From the Diesel Burner
Step 5: Disconnect the Diesel Burner’s Thermostat Wires From the Aqua-Hot
1. Using a Phillips head Screw Driver loosen the screws
securing the thermostat access cover in place, and remove
the thermostat access cover.
Thermostat
Access Cover
1. Disconnect the thermostat wires by firmly
pulling on the pink connectors. Remove the
wires from the wire access slot.
Wire Access
Slot
1. Using Pliers loosen the constant tension clamps securing the fuel lines to the diesel burner, and slide away from the burner.
2. Remove the fuel lines from the diesel burner.
NOTE:
Before Disconnecting the fuel lines, it is recommended to use hose pinch off pliers on the rubber fuel lines, to shut the flow
of fuel off, while the burner is removed.
Figure 31a
Figure 31b
Figure 32