© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
A
PPENDIX
E: A
QUA
-H
OT
M
AINTENANCE
Step 9: Clean Ignition Electrodes and Flame Sensor
1. Ignition electrodes -
A. Polish away any carbon deposits that may have baked onto the metal tips of the ignition
electrodes with a course sponge.
2. Flame Sensor -
A. For light dirt, dust, and/or carbon deposits, simply wipe off the flame sensor with a soft
cloth.
B. Should heavy carbon deposits be present, completely remove the flame sensor from the
photo disc and clean with brake cleaner.
Metal Tips
Flame Sensor
Figure E9