— Page 43 —
© 2011 Aqua-Hot
®
AHE-100-02S Hydronic Heating System Service Manual—Rev. B
S
ECTION
7: D
ETACHING
AND
R
EATTACHING
THE
D
IESEL
B
URNER
Reattaching the Diesel Burner to the Aqua-Hot
1. Install the burner on the Aqua Hot and swing the eye bolts over the mounting tabs on the diesel
burner. The eye-bolt nuts can then be tightened by using a 10mm socket wrench with a 10 inch long
extension. Use extreme caution when tightening down the eye-bolt nuts, over tightening of the eye-
bolt nuts can cause the aluminum blower casing to crack.
(Torque Specifications = Approximately 20-40 in. lbs.)
When reattaching the diesel-burner be sure to properly align the diesel-burner before tightening the eye-bolt nuts. Also, visually
inspect all of the rubber grommets on the top and bottom of the diesel-burner’s cast-aluminum blower casing to ensure they are in
place.
DO NOT
over tighten the eye-bolt nuts. Torque specifications are: approx. 20-40 in. lbs. An improper alignment and/or
over tightening of the eye-bolt nuts can cause damage to the diesel-burner’s cast aluminum blower casing.
CAUTION!
1. Install the fuel lines onto the fuel pipe banjo fittings.
2. Using pliers loosen, and slide the constant tension clamps back into place, to secure the fuel lines.
3. Remove the hose pinch off pliers.
Figure 33
Figure 34a
Figure 34b
Step 1: Reattach the Fuel Lines to the Diesel Burner
CAUTION!
The Aqua Hot is equipped with a fuel supply check valve. If the fuel lines are hooked up backwards on the burner. Serious damage
may occur to the diesel burner fuel pump.
Step 2: Reattach the Diesel Burner to the Aqua Hot
Summary of Contents for AHE-100-02S
Page 1: ...SERVICE MANUAL 2011 Aqua Hot Heating Systems Inc AHE 100 02S ...
Page 2: ... Page 2 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 104: ... Page 104 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...
Page 105: ... Page 105 2011 Aqua Hot AHE 100 02S Hydronic Heating System Service Manual Rev B ...