A n r it s u
5 0
3. Set the
Group
search range. The group number is the scrambling code divided by 8. For
example, SC (scrambling code) 12 = group 1, cell 4.
4. Set the
Cell
search range. The cell number is the division modulus. For example, SC
(scrambling code) 12 = group 1, cell 4.
5. The
Secondary Code
and the
Channelization Code
ranges should be set from 0 to 0 for
scanning only the P-CPICH.
6. Select the
Search Method
. SCH means that the P-CPICH are searched using P-SCH and
S-SCH. P-CPICH means that the P-CPICH are searched without using P-SCH and S-SCH.
♦
Note that the P-CPICH method is much slower than the SCH method.
7. Click
OK
to accept the settings and to return to the
Measurement Properties
dialog.
8.
Data processing method
defines how the scanner will process samples before reporting.
9.
PN threshold
defines the limit above which Ec/N0 peaks must go if Aggregated data
processing method is used.
♦
In pilot scanning mode, the RSSI is always measured for each channel.
♦
In pilot scanning mode the P-CPICH Ec/N0 and RSCP are always measured for each
scrambling code.
10. After making the appropriate settings, click
OK
and
OK
again and go to online mode to start
the scanning.
11. A green light on the scanner
Device Status
window should start blinking. This means that
the device is working properly and scanning using the default settings. In TOP-N Mode this
may take a few seconds.
12. Click the
Start Recording
button
to start recording the results in an output file.
Summary of Contents for NEMO FSR1
Page 1: ...Version 6 20 SCANNER GUIDE...