N e m o F S R 1
5
NEMO FSR1
CONNECTING NEMO FSR1 SCANNER
Nemo FSR1 scanner is powered by 10 to 16 VDC. AC operation for the standalone receiver is
achieved by using the optional AC power supply. The AC power supply is designed to work with
100 - 240VAC 50/60Hz. For other voltages or line frequencies contact Anite for the correct
supply.
The standard AC supply is rated at 130 Watts. Actual power requirements will vary depending
number of downconverters installed and the receiver tasking. The maximum power requirement
of the scanner is 50 Watts.
DC operation for the standalone receiver can be achieved by connection to a vehicle 12-volt
system. The following table is provided to budget the system current requirements for various
configurations.
Platform configuration/Module
12 VDC current requirement
Basic system w/ single downconverter
3.0 A
Two downconverter system
3.6 A
The estimates given for the scanner assume maximum utilization of the processing capabilities.
∇
Connecting the Nemo FSR1:
1. Connect an antenna cable to scanner RF input. If you are measuring with two
downconverters, connect an antenna in both RF inputs (see picture below).