A n r it s u
3 4
♦
The following steps apply to Anritsu ML8720B and ML8720C scanners. If you are
measuring with the Anritsu ML8740A or Anritsu ML8740B scanner, see step 12.
4. Connect the null modem cable to the scanner COM port that can be found below the power
switch.
5. Connect the null modem to one of the PC COM ports
6. Turn the power on in the scanner. The Power led should light up.
7. The scanner should now start, wait until the scanner has started
8. Press the
Menu
button in the scanner.
9. Use the arrow keys and the
Sel
button to select
Interface and Behavior
.
10. Check that the settings are as follows. If not, change them using the arrow keys and the
Sel
button (note that the selected item will be underlined as soon as you use the arrow buttons
to switch to another line). To exit the dialog without saving, press the
F4
button (Cancel). To
exit the dialog and save the modified settings, press the
F5
button (OK).
•
COM1 Protocol: Direct
•
COM1 Baud Rate: 38400
or
57600
or
115200
•
COM1 Stop Bit(s): 1
•
COM1 Data Length: 8
•
COM1 Parity: None
♦
The baud rate 115200 is the fastest option.
♦
Note! Memorize the baud rate. It is needed when starting the device.
Summary of Contents for NEMO FSR1