![Analog Devices ADIS1700 Series User Manual Download Page 99](http://html1.mh-extra.com/html/analog-devices/adis1700-series/adis1700-series_user-manual_2939752099.webp)
*returnedMeasurementCount, SNAP_UINT16 *lastMeasurementId, TimeSpan
*lastMeasurementTime)
Table 7-125:
Get Measurements Command - Header
Field Name
Type
Notes
Module ID
U1
0x12
Reserved1
U1
0
Command ID
U2
0x11
Version
U4
2
Reserved2
U4
0
Payload Size
U4
4
Result
U4
0
Table 7-126:
Get Measurements Command - Payload
Field Name
Type
Notes
Format
U2
See the
Table 7-129 Get Measurement Format
ta-
ble
Number of Samples
U2
1– 1000
Table 7-127:
Get Measurements Response - Header
Field Name
Type
Notes
Module ID
U1
0x12
Reserved1
U1
0
Command ID
U2
0x11
Version
U4
2
Reserved2
U4
0
Payload Size
U4
12 + N × M × 2 + M × 4
Result Status
U4
0x50 – Invalid Format
Table 7-128:
Get Measurements Response - Payload
Field Name
Type
Notes
Format
U2
See the
Table 7-129 Get Measurement Format
ta-
ble
Number of Samples
U2
N = 0 – 1000
Last Meas. ID
U2
0 – 65535
DaysSince2000
U2
0 – 65535 (years 2000 to 2179)
IMU Module Messages
7–50