![Analog Devices ADIS1700 Series User Manual Download Page 117](http://html1.mh-extra.com/html/analog-devices/adis1700-series/adis1700-series_user-manual_2939752117.webp)
Table 7-172:
Get Log Data Command - Payload (Continued)
Field Name
Type
Notes
Num of Types
U1
N. Required types list count.
When set to 255 the following list
shall not be added to the com-
mand.
N
2
×
Type ID
U1
Required types list item [0..254].
Type ID 255 codes the invalid
type.
Table 7-173:
Get Log Data Response - Payload
Field Name
Type
Notes
Module ID
U1
0x40
Reserved1
U1
0
Command ID
U2
0x32
Version
U4
1
Reserved2
U4
0
Payload Size
U4
where L
i
is the chuck size
Result Status
U4
0
Table 7-174:
Get Log Data Response - Payload
Field Name
Type
Notes
Start Index
U4
Items Count
U4
N
Remaining Items
U4
Next Index
U4
Next Offset
U4
× N
Type ID
U1
Total Size
U3
Sequence ID
U4
Offset
U4
Chunk Size
U4
Let L
i
be the chuck size
Storage Module Messages
7–68