Table 7-119:
Set ADVS200x LUT Response- Header
Field Name
Type
Value
Notes
Module ID
U1
0x10
Reserved1
U1
0
Command ID
U2
0x23
Version
U4
1
Reserved2
U4
0
Payload Size
U4
0
Result Status
U4
0 if the LUT has been successfully
set.
Self Test
The Self Test command runs the defined sequence of electrical tests. The response reports availability and result of
each test.
The
Self Test ID Descriptions
table specifies the available self tests.
Self Test ID Descriptions
Test ID
Test Name
Description
Result Type
Notes
1
ADVS200x Reset
Modifies the first and last entry
of the LUT.
Resets the ADVS200x.
Reads the same two entries and
verifies that they match the de-
fault ADVS200x LUT values.
Result: Pass(0)/Fail(1)
Result Value: 0
2
PPI Port
Uses the ADVS200x PPI test
mode. Verifies that each of the
13 pins of the PPI port can be
set to 0 or 1 while all the other
pins are set to the complemen-
tary value. This requires 26
tests.
Result: Pass(0)/Fail( n)
Result Value:
Test word that failed if
any.
n > 0 is the subtest which failed
if any.
(n-1)%13 gives the pin which
failed where PPI pins 0..9 are
the data pins while pins 10..12
are H.Sync V.Sync and F.Sync.
If n <= 13 (resp. n > 13) the
test failed to set the failed pin
to 1 (resp. to 0) while all the
other PPI pins where set to 0
(resp. to 1).
Camera Module Messages
7–46
ADIS1700x Vision-Sensing Camera Module User Guide