![Analog Devices ADIS1700 Series User Manual Download Page 64](http://html1.mh-extra.com/html/analog-devices/adis1700-series/adis1700-series_user-manual_2939752064.webp)
Table 7-28:
Clear Sections Response- Header (Continued)
Field Name
Type
Notes
Version
U4
1
Reserved2
U4
0
Payload Size
U4
0
Result Status
U4
0
Read Section
Reads a section. Offset and size are expected to be expressed in sectors. The sector size is provided by the
Table 7-29:
Read Section Command - Header
Field Name
Type
Notes
Module ID
U1
1
Reserved1
U1
NV Storage medium ID
Command ID
U2
0x22
Version
U4
1
Reserved2
U4
0
Payload Size
U4
12
Table 7-30:
Read Section Command - Payload
Field Name
Type
Notes
Section ID
U4
Section ID to read
Offset [sectors]
U4
Relative offset with respect to the section start
Size [sectors]
U1
N
Table 7-31:
Read Section Response- Header
Field Name
Type
Notes
Module ID
U1
1
Reserved1
U1
NV storage medium ID
Command ID
U2
0x22
Version
U4
1
Reserved2
U4
0
Payload Size
U4
12 + Size
Result Status
U4
0
Bootloader Messages
ADIS1700x Vision-Sensing Camera Module User Guide
7–15