![Analog Devices ADIS1700 Series User Manual Download Page 120](http://html1.mh-extra.com/html/analog-devices/adis1700-series/adis1700-series_user-manual_2939752120.webp)
Product Identification
The product ID and name are a combination of the software type ID and device ID .
PRODUCT_ID = (SOFTWARE_T (DEVICE_ID << 8))
PRODUCT_NAME = DEVIC ”_” + SOFTWARE_TYPE_NAME
For example, for the ADIS1700x Camera application where:
•
Software Type ID = 1
•
Device ID = 2
•
Device Name = ADIS1700x
•
Software Type Name = Camera
The PRODUCT_ID = 512 and the PRODUCT_NAME = "ADIS1700x-Camera"
Error Messages
The messages shown in the
Error Messages
table are reported in the
Last Error Message
field of the
response.
Table 8-4:
Error Messages
Error String
Description
Applicable Module
FW not valid, max
launches exc.
Bootloader has expired the maximum number of attempts to
launch (boot) an unvalidated application. The application cannot
launch. The bootloader tries to recover a restore point, if any are
available. If a restore point is not available, the bootloader waits for
the user to update a new firmware.
Bootloader
No valid firmware
No valid firmware is present in the “Current Application Firm-
ware” section
Bootloader
WD RST on Current
App. FW
A watchdog reset caused the last system reset. It is likely that the
watchdog was caused by the firmware loaded in the Current Appli-
cation Firmware” section
Bootloader
Camera Failure. Resetting
camera
Camera service failed to initialize or to start/stop the camera or to
set/get registers or LUT.
All except bootloader
Error Messages
8–2
ADIS1700x Vision-Sensing Camera Module User Guide