Firmware Pages and Descriptions
56
NXP-TPI/4 NetLinx Touch Panel Interface
Setup Page
The page (FIG. 40) centers around the basic properties used by the touch device connected to the
NXP-TPI/4 such as: Connection Status of the TPI/4, Display Timeout, Inactivity Page Flip Time, and
Inactivity page file information for the TPI/4 device.
The elements of the Setup page are described in the table below:
G4 Setup Navigation Button Elements (Cont.)
Video Adjustment:
Press the Video Adjustment button to access the main video page (either Video
Setup for a TP4-VID or RGB Setup for a TP4-RGB) where you can set the
video properties for incoming signal.
• The displayed page is associated to the TP4 card being used on a selected
Slot ID (
default = Slot 1
).
• A TPI/4 can use any combination of up to four (4) TP4 cards
(TP4-RGB or TP4-VID).
• Refer to the
Video Adjustment - Video Adjustment
section on page 63 for
more detailed information.
FIG. 40
Setup page
Setup Page Elements
Exit:
Returns you to the Main touch panel page. In this case, the previous page is the
default Main page.
Connection Status icon:
This visual display of the connection status allows the user to have a current
update of the TPI/4’s connection status regardless of what page is currently
active.
• A Lock only appears on the icon if the TPI/4 has established a connection with
a currently secured target Master (
requiring a username and password
).
Connection Status
Red
Connection Status icon -
Green
Connection Status icon -
indicates no connection to
indicates communication
a Master
to a Master
Summary of Contents for NetLinx NXP-TPI/4
Page 38: ...TPI 4 and Panel Interface Setup 32 NXP TPI 4 NetLinx Touch Panel Interface...
Page 60: ...Upgrading TPI 4 Firmware 54 NXP TPI 4 NetLinx Touch Panel Interface...
Page 138: ...Troubleshooting 132 NXP TPI 4 NetLinx Touch Panel Interface...
Page 147: ...Appendix 141 NXP TPI 4 NetLinx Touch Panel Interface...