1-63
S-104-100
Revised 09/2004
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
CLAMPING
Adjusting the Clamp Pressure
The clamp foot pressure has been factory set for medium / heavy weight materials. Additional pressure
may be required for light weight materials. To adjust, perform the following steps:
1. Loosen nut
A
,
B
and turn adjustment screw
C
up or down (up increases clamp pressure; down
decreases clamp pressure) as necessary.
2. The correct amount of pressure is obtained when the material is held firmly by the clamp foot. Once
this has been achieved, re-tighten nuts
A
and
B
.
CAUTION:
Avoid using excessive pressure.