1-91
S-104-100
Revised 09/2004
e-mail: [email protected]; [email protected]; website: www.amfreece.com
Phones: +420 582 309 146 (Service), +420 582 309 286 (Spare Parts); Fax: +420 582 360 606
PREVENTIVE MAINTENANCE
It is necessary to establish a good preventive maintenance program and adhere to it. It is necessary that the
oil is checked and replenished when needed, and the machine be freed of any pieces of material and loose
thread on a daily basis. To do this, it is recommended that you have the following items on hand for the
everyday upkeep and cleaning of your machine.
oil
vacuum clearner / paint brush / parts brush
NOTE: DO NOT
use an air blower in place of a vacuum. The air blower could blow particles into the
cam, thus damaging it.
Below is a Periodic Maintenance Checklist which lists the types of preventive maintenance to be done,
and how often they need to be done”
DAILY
Oil machine
Remove lint from loopers and spreaders
WEEKLY
Check belt tension
Inspect and replace (if necessary) knife and block
MONTHLY
Check Stop Motion
Check for loose hardware, replace parts as necessary
Check throat plate for wear, replace if necessary