amplifiers. Note that only one RPV input is available so in three phase modes, all three outputs
will track the same RPV DC input signal.
A 0 to +10 VDC signal will provide a 0 to full-scale voltage output on the selected voltage range.
To enable the RPV mode, press the MENU key until the CONTROL screen and scroll to the
ALC setting entry. If the ALC is set to REG or ON, turn if OFF first. Then scroll to the VOLT REF
entry. Select EXT to use the RPV (remote programming voltage).
The presence of the RPV option is indicated by the –RPV field in the model number on the serial
tag. Note that the –EXT and –RPV options are mutually exclusive so only one or the other can
be present.