12
2.1.2 Output
Output Parameter
Specification
Modes
AC
Current (as a function of selected compliance voltage range):
Ranges (L-N):
3000CS/ 4500CS Series
135V CVR
1
0 – 14.81 Arms, three phase mode
0 – 44.44 Arms, single phase mode
3000CS Max. current is power limited above 67.5V.
4500CS Max. current is power limited above 101V
270V CVR
0 – 7.4 Arms, three phase mode
0 – 22.22 Arms, single phase mode
3000CS Max. current is power limited above 135V.
4500CS Max. current is power limited above 202V
Resolution: 0.01
A
Ranges (L-N):
9000CS/2
135V CVR
0 – 29.62 Arms, three phase mode
0 – 88.88 Arms, single phase mode
Max. current is power limited above 101V
270V CVR
0 – 14.81 Arms, three phase mode
0 – 44.4 Arms, single phase mode
Max. current is power limited above 202V
Resolution: 0.01
A
Ranges (L-N):
13500CS/3
135V CVR
0 – 44.44 Arms, three phase mode
0 – 133.3 Arms, single phase mode
Max. current is power limited above 101V
270V CVR
0 – 22.22 Arms, three phase mode
0 – 66.66 Arms, single phase mode
Max. current is power limited above 202V
Resolution: 0.01
A
Ranges (L-N):
18000CS/4
135V CVR
0 – 59.24 Arms, three phase mode
0 – 177.76 Arms, single phase mode
Max. current is power limited above 101V
270V CVR
0 – 29.62 Arms, three phase mode
0 – 88.86 Arms, single phase mode
Max. current is power limited above 202V
Resolution: 0.01
A
Programming
Accuracy:
3 Phase mode: ± (0.1% + 0.05 A) from .5A to FS
1 Phase mode: ± (0.1% + 0.15 A) from .5A to FS
Distortion THD
2
:
Standard:
< 1.2 %
[60 - 500 Hz]
1
CVR = Compliance Voltage Range.
2
The distortion specification for the CS Series applies at full-scale current, full resistive load conditions, using 30Khz
LP Filter on distortion analyzer.