CHAPTER 5: SETUP SOFTWARE
UB25 LINEAR DC RESISTANCE WELDING CONTROL
990-665
5-25
I.D. Number
The host computer may be used to talk with multiple Power Supplies using a single RS-485
communications line. Each Power Supply sharing that line
must
have a unique identification number. To
enter an identification number for the Power Supply, proceed as follows:
1
From the
MAIN MENU
, press the
5
key
to go to the
COMMUNICATIONS
MENU.
2
From the
COMMUNICATIONS
MENU
screen, press the
2
key to get the
I.D.
NUMBER
entry screen.
3
Enter a two-digit number, from
01
to
99
,
in the
I.D. NUMBER
field.
4
Press the
MENU
key to get the
COMMUNICATION
menu screen. This time the
I.D. NUMBER
line will display your I.D. number entry.
5
Press
MENU
to return to the
MAIN MENU.
Baud Rate
The baud rate at which the data is sent must match the baud rate of the host computer. To enter the baud
rate, proceed as follows:
1
From the
COMMUNICATION
menu,
press the
3
key to get the
BAUD RATE
selection screen.
2
Use the numeric keypad to select the
baud rate of the receiving device. The
display automatically returns to the
COMMUNICATION
menu which
shows the new baud rate.
3
3
Press
MENU
to return to the
MAIN MENU.
I.D. NUMBER
I.D. NUMBER
: 01
NUMBER Change, MENU Previous menu
BAUD RATE
1. 1200
6. 19.2K
2. 2400
7. 28.8K
3. 4800
4. 9600
4. 14.4K
NUMBER Change, MENU Previous menu