CHAPTER 5: SETUP SOFTWARE
UB25 LINEAR DC RESISTANCE WELDING CONTROL
5-8
990-665
Weld Fire Lockout Charge % Setting
1
From the
WAVEFORM CHECK
menu,
press the
5
key to access the
WELD
FIRE LOCKOUT
screen.
2
Use the numeric keypad to enter the
required amount of energy in the
capacitor bank before the next weld is
allowed.
3
Press
MENU
to return to the
WAVEFORM CHECK
menu. The
WELD FIRE LOCKOUT CHRG%
line will display your programmed
setting along with the actual
%
CHARGE
from the most recent weld.
Footswitch Weld Abort
1
Go to the
SETUP 1
screen.
2
Press the
1
key to toggle between
FOOTSWITCH WELD ABORT ON
and
FOOTSWITCH
WELD ABORT OFF
.
STATE
PREFERRED APPLICATION
FUNCTION
ON
Human operated
welding
stations
where the operator holds parts.
Allows you to abort the weld process by
releasing the foot switch used with an air-
actuated weld head. Will also terminate the
welding sequence
if
the footswitch is
opened
before the firing switch is initiated.
OFF
Computer or PLC controlled
welding
stations. Also, for human
operated stations where tooling holds
the parts, and where the welding
sequence can be initiated with a single
momentary start pulse.
Once the footswitch (second level of a two
level footswitch) and firing switches have both
been
closed
, the welding sequence will
continue to its conclusion regardless of
footswitch or firing switch position.
3
Keep pressing the
MENU
key on the front panel to return to the
MAIN MENU
.
WELD FIRE LOCKOUT CHRG%
WELD FIRE LOCKOUT CHRG%:
90
NUMBER Change, MENU Previous menu