CHAPTER 5: SETUP SOFTWARE
UB25 LINEAR DC RESISTANCE WELDING CONTROL
990-665
5-21
Section VII. Special Functions
Copy a Schedule
1
From the
MAIN MENU
, press the
3
key
to get to the
COPY SCHEDULE
screen.
NOTE
: There are two fields in the
COPY SCHEDULE
screen. These
fields determine which schedule will be
copied (
source
) and which schedule will
be overwritten (destination). Both fields
initially contain the number of the schedule most recently displayed.
2
Use the numeric keypad to enter the number of the
source
schedule.
3
Press the schedule key to select the
destination
schedule number field.
4
Use the numeric keypad to enter the number of the
destination
schedule.
5
Press the schedule key. The contents of the source schedule will be copied to the destination
schedule, overwriting the previous contents of the destination schedule.
NOTE
: All monitor settings and limits are also copied.
Reset Defaults
The Power Supply is manufactured and shipped with the factory-set defaults. Any of these settings may
be changed.
Defaults for Setup Menu 1
SYSTEM PARAMETER
DEFAULT SETTING
Foot Switch Weld Abort
OFF
Switch Debounce Time
10 ms
Firing Switch
AUTO
Input Switch Select
MECH OPEN
Control Signals Select
MECH OPEN
COPY SCHEDULE
COPY SCHEDULE [ 1 ] TO SCHEDULE [ 1 ]
NUMBERS followed by SCHEDULE