![Amada UB25 Operation Manual Download Page 83](http://html1.mh-extra.com/html/amada/ub25/ub25_operation-manual_2915806083.webp)
CHAPTER 5: SETUP SOFTWARE
UB25 LINEAR DC RESISTANCE WELDING CONTROL
990-665
5-23
Defaults for Relay Menu
SYSTEM PARAMETER
DEFAULT SETTING
Relays 1 through 4
ON WHEN ALARM
It is common to change system and schedule
settings when you customize the Power Supply
for specific welding needs. If you wish to reset
the Power Supply to the original default settings,
go to the
MAIN MENU
, then press the
8
key to
get the
RESET DEFAULTS
menu.
This menu allows you to reset all system
programmed parameters and all weld schedules to
the original factory default settings.
Reset System Parameters
1
From the
MAIN MENU
, press the
8
key
to go to the
RESET DEFAULTS
menu.
2
From
RESET DEFAULTS
, press the
1
key to go to the
RESET SYSTEM
PARAMETERS?
menu.
3
Press the
2
key to select
YES
. This will automatically reset the system parameters to the
factory defaults and return the screen to the
RESET DEFAULTS
menu.
4
Press
MENU
to return to the
MAIN MENU.
Reset All Schedules
1
From the
RESET DEFAULTS
menu,
press the
2
key to get to the
RESET
ALL SCHEDULES?
menu.
2
Press the
2
key to select
YES
. This will
automatically reset all weld schedule
parameters to the factory defaults and
return the display to the
RESET
DEFAULTS?
screen.
3
Press
MENU
to return to the
MAIN
MENU.
RESET SYSTEM PARAMETERS?
1. NO
2. YES
NUMBER Select, MENU Previous menu
RESET DEFAULTS
1. RESET SYSTEM PARAMETERS
2. RESET ALL SCHEDULES
EPROM DATE: XX-XX-XX XX:XX VX.XX
NUMBER Select, MENU Previous menu
RESET ALL SCHEDULES?
1. NO
2. YES
ALL WELD SCHEDULES ARE RESET
NUMBER Select, MENU Previous menu