9. External Communication Function
9-9
3
At the occurrence of fault
In case of one fault
Data strings: E: 01, 06 [CR][LF]
A B C D
Ex.) E: 01,06[CR][LF]
In case of five faults
Data strings: E: 01, 06, 07, 08, 09, 10 [CR][LF]
A B C C C C C D
Ex.) E: 01,06,07,08,09,10[CR][LF]
Item
Character
string
Content Range
A
E:
Fault send code
E: (fixed)
B
**,
Schedule No.
01 to 31
C **
*1
Fault code
01 to 20
D
[CR][LF]
CR, LF code
0DH 0AH (fixed)
*1: Up to five fault codes are output. If two or more fault codes exist, the codes are separated
with “,”. If no fault exists, E00 is output.