MD Series
9. External Communication Function
9-23
9) Specified code No.: S08 (COMMUNICATION SETTING screen)
Data strings: When reading Device No. 01 (Set 000 for Schedule No.)
Host PC -> MD series
#01R000S08[CR][LF]
MD series -> Host PC
!01000S08: 0, 0, 01, 0 [CR][LF]
A B C D
Item
Character
string
Content Range
Increment/
Decrement
A *,
COMMUNICATION CONTROL:
Communication function setting
0: OFF
1: DATA OUTPUT
2: BI-DIRECTION
0 to 2
1
B *,
COMMUNICATION MODE:
Communication mode setting
0: B MODE
1: C MODE
0 to 1
1
C **,
COMMUNICATION UNIT#:
Device No.
1 to 31
1
D *
COMMUNICATION SPEED:
Communication speed
0: 9600bps
1: 19200bps
2: 38400bps
0 to 2
1
*1: When changing the communication setting, change the communication setting on the host
computer side, too.