MD Series
6. Explanation of the Screen
6-6
〕
〕
〕
(e) VOLT
Selects whether to display the waveform of voltage and the average
value/peal value.
Refer to (i) for switching of the average value and the peak value.
(f) POWER
Selects whether to display the waveform of power.
(g) RESIST
Selects whether to display the waveform of resistance.
(h) PEAK or AVE
Selects the average value or peak value of current.
Note) Average value and peak value can not be displayed simultaneously.
(i) PEAK or AVE
Selects the average value or peak value of voltage.
Note) Average value and peak value can not be displayed simultaneously.
(4) Setting Upper/Lower Limits for Judgment
(COMPARATOR Screen)
Screen for setting the upper and lower limits of current, voltage, and power
(called monitor values).
Measured values within the set monitor value range are judged good, and those
out of the range are judged no good. (If measured values and monitor values are
the same, they are judged good.)
When the judgment is no good, a fault signal or a caution signal is output.
(a) SCH.#
Denotes No. of SCHEDULE (welding condition).
Input the schedule number to set. After welding, the number is switched to the
schedule number of the welding.
(a)
(b)
(c)
(d)
(e)