MD Series
9. External Communication Function
9-11
Item Command
Code
Writing of data
# Device No. W Schedule No. Specified
code No. : Data
4
Ex.: Write Schedule No. 8 of Device No. 01 and data of Specified code No. S01.
Host PC -> MD series
# ID1 ID2 W SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
#01W008S01: Data [CR][LF]
MD series -> Host PC
! ID1 ID2 SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
!01008S01: Data [CR][LF]
・
See
2
Data code table for the data order.
Reading of fault data
# Device No. R Schedule No. Specified
code No.
5
Ex.: Read fault data of Device No. 01
Host PC -> MD series
# ID1 ID2 R SH1 SH2 SH3 CD1 CD2 CD3 [CR] [LF]
#01R000S13[CR][LF]
MD series -> Host PC
! ID1 ID2 SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
!01001S13: Data [CR][LF]
・
Write 000 for Schedule No. (SH1, SH2, SH3).
・
Write S13 for Specified code No. (CD1, CD2, CD3).
・
See
2
Data code table for the data order.
・
Schedule No. for data output from the MD series becomes last-welded Schedule No.
Resetting of fault
# Device No. W Schedule No. Specified
code No. : Data
6
Ex.: Reset the fault of Device No. 01.
Host PC -> MD series
# ID1 ID2 W SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
#01W000S13: E00[CR][LF]
MD series -> Host PC
! ID1 ID2 SH1 SH2 SH3 CD1 CD2 CD3 : Data [CR] [LF]
!01001S13: E00[CR][LF]
・
Write 000 for Schedule No. (SH1, SH2, SH3).
・
Write S13 for Specified code No. (CD1, CD2, CD3).
・
Schedule No. for data output from the MD series becomes last-welded Schedule No.
・
E00 is output for data.